|本期目录/Table of Contents|

[1]李亮,魏端丽,曹南南,等.聚乙烯亚胺肝素涂层改性聚氯乙烯与表征[J].武汉工程大学学报,2014,(05):34-37.[doi:103969/jissn16742869201405008]
 LI Liang,WEI Duan li,CAO Nan nan,et al.Modification of polyvinyl chloride with polyethyleneimineheparin coating and characterization[J].Journal of Wuhan Institute of Technology,2014,(05):34-37.[doi:103969/jissn16742869201405008]
点击复制

聚乙烯亚胺肝素涂层改性聚氯乙烯与表征(/HTML)
分享到:

《武汉工程大学学报》[ISSN:1674-2869/CN:42-1779/TQ]

卷:
期数:
2014年05期
页码:
34-37
栏目:
材料科学与工程
出版日期:
2014-05-31

文章信息/Info

Title:
Modification of polyvinyl chloride with polyethyleneimineheparin coating and characterization
文章编号:
16742869(2014)05003404
作者:
李亮魏端丽曹南南汪洋
武汉工程大学材料科学与工程学院,湖北 武汉 430074
Author(s):
LI LiangWEI DuanliCAO NannanWANG Yang
School of Materials Science and Engineering,Wuhan Institute of Technology,Wuhan 430074,China
关键词:
抗凝血脱落率肝素
Keywords:
anticoagulationexpulsion rateheparin
分类号:
TM 344.1
DOI:
103969/jissn16742869201405008
文献标志码:
A
摘要:
为了改善医用聚氯乙烯材料的生物相容性和抗凝血性,采用新型肝素涂层技术对医用聚氯乙烯材料表面进行改性,研究了涂层中肝素的稳定性.利用聚乙烯亚胺-肝素结合的方法,将肝素涂层固定在医用聚氯乙烯材料表面.使用傅里叶红外光谱仪对其进行测试,绘制肝素钠和聚乙烯亚胺肝素复合物的标准浓度曲线,通过分光光度法测定了医用聚氯乙烯材料表面肝素的含量,并计算肝素的脱落率.实验表明,在聚氯乙烯表面肝素与聚乙烯亚胺通过阴阳离子相互作用而结合,而且在聚氯乙烯面的肝素含量为944.1 μg/cm2,浸泡在生理盐水中700 h后,肝素的释放速率先快后慢,最终趋于稳定,其表面肝素脱落量仅为0.78%.这说明聚乙烯亚胺-肝素涂层改性的聚氯乙烯材料具有良好的肝素稳定性与极低的脱落率.
Abstract:
To improve the biological compatibility and antithrombogenicity of polyvinyl chloride (PVC) materials of medical grade,the polyethyleneimineheparin (PEIH) coating technique was used to modify the surface of PVC.The stability of heparin coated on the surface of PVC was studied.Fourier transform infrared spectroscope was carried out to characterize the materials.The concentration of coated heparin was calculated and heparin releasing rate was evaluated by toluidine blue spectrophotometry.The results show that heparin and polyethyleneimine can be interacted with each other via the anioncation interactions;the heparin concentration on PEIHcoated PVC surface is 944.1 μg/cm2;the heparin releasing ratio is only 0.78% after soaked in saline for 700 hours,which indicates that PEIHcoated PVC materials have good heparin releasing stability and extremely low heparin releasing ratio.

参考文献/References:

[1]APOSTOLAKIS E,KOLETSIS E,DOUGENIS D.Succinct history of greek cardiac surgery[J].Journal of Cardiac Surgery,2008,23(5):499502.[2]CREMER J,MARTIN M,REDL H,et al.Systemic inflammatory response syndrome after cardiac operations[J].The Annals of Thoracic Surgery,1996,61(6):17141720.[3]杨军,曹谊林,刘伟.组织工程化皮肤及临床应用研究进展\[J\].国外医学:生物医学工程分册,2004,27(5):274277.YANG J.Research progress in tissueengineered skin and its clincal application[J].Foreign Medical Sciences:Biomedical Engineering Fascicle,2004,27(5):274277.[4]KUTAY V,NOYAN T,OZCAN S,et al.Biocompatibility of heparincoated cardiopulmonary bypass circuits in coronary patients with left ventricular dysfunction is superior to PMEAcoated circuits[J].Journal of Cardiac Surgery,2006,21(6):572577.[5]RUBENS F D,MESANA T.The inflammatory response to cardiopulmonary bypass:a therapeutic overview[J].Perfusion,2004,19(1):512.[6]STEVENS K N J,ALDENHOFF Y B J,VAN DER VEEN F H,et al.Bioengineering of improved biomaterials coatings for extracorporeal circulation requires extended observation of bloodbiomaterial Interaction under Flow[J].Bio Med Research International,2008:29464.[7]HIOKI I,NISHIKAWA M,ONODA K,et al.A heparincoated circuit maintains platelet aggregability in response to shear stress in an in vitro model of cardiopulmonary bypass[J].Thrombosis and HaemostasisStuttgart,1998,80:437442.

相似文献/References:

备注/Memo

备注/Memo:
收稿日期:20140313基金项目:湖北省自然科学基金(2012FFA021)作者简介:李亮(1978),男,湖北黄石人,教授,博士. 研究方向: 功能复合材料制备与应用.
更新日期/Last Update: 2014-06-15